Hygrothermostat for simultaneous control or monitoring of temperature and humidity in offices, residential properties and hotels, as well as swimming pools, conservatories and residential baths and suitable for all types of heating. The device can be operated using 24 V~ or 230 V~ as required. With electric underfloor heating, ensure that the output from the heating cannot overheat the screed, even during continuous operation. With hot water heating systems, a max. of 10 valves (closed when de-energised) should be connected to the heating output, or a max. of 5 valves (open when de-energised) to the cooling output. When cooling, a max. of 5 valves (closed when de-energised) should be connected to the cooling output, or a max. of 10 valves (open when de-energised) to the heating output. Where necessary, thermal cut-outs may also need to be installed. Max. switching current: Dehumidifying (terminal 9) 5 (0.2) A, humidifying (terminal 8) 3 (0.2) A, heating (terminal 1) 10 (4) A at 230 V AC / 1 (1) A at 24 V AC, cooling (terminal 2) 5 (2) A at 230 V AC / 1 (1) A at 24 V AC, switching power: Terminal 9: 1150 W, terminal 8: 690 W, terminal 1: 2300 W at 230 V AC / 24 W at 24 V AC, terminal 2: 1150 W at 230 V AC / 230 W at 24 V AC
  • Art.-Nr.: MA220000

    Technical data

    Ambient temperature, lower value0 °C
    Ambient temperature, upper value50 °C
    AssemblyComplete device
    Bearing temperature, lower value-20 °C
    Bearing temperature, upper value60 °C
    Can be read offNo
    ColourPure white
    Contact interlockingNo
    Control range, lower value10 °C
    Control range, upper value35 °C
    Cooling control functionYes
    Degree of contamination2
    Depth26 mm
    DesignBerlin 3000
    Digital displayNo
    DisplayNo
    Electric connectionScrew terminals
    External settingYes
    Heating control functionYes
    Height110,7 mm
    Housing materialPlastic ABS
    Humidify / dehumidify control functionYes
    Internal settingNo
    Maximum air humidity (non-condensing)95 % r.H
    Maximum switching current10 (4) A
    Maximum switching voltage230 V AC, 50 Hz
    Mechanical range reductionYes
    MediumAir, not aggressive
    Minimum switching current100 mA
    Minimum switching voltage24 V AC / 50 Hz
    Mounting / attachmentSurface mounting
    NEMA type of protectionOther
    Number of outputs6
    On / Off switchYes
    Operating voltage230 V AC / 50 Hz or 24 V AC / 50 Hz
    OperationRotary knob and switches
    Output signalSwitching
    Potential free switching contactNo
    Protection classII, following appropriate mounting
    RAL colour number (similar)9010
    Safety and EMCIn accordance with DIN EN 60730
    SealableNo
    Sensor elementPlastic fibres and bimetal
    Setting range, rel. air humidity lower value30 %
    Setting range, rel. air humidity upper value100 %
    Surface propertiesMatt
    Switching contact2 two-way contacts
    Switching differenceApprox. 4% r.H. approx. 1 K
    Switching difference, can be adjustedNo
    Switching elementMicroswitch and bimetal
    Switching power2300 W
    Type of protectionIP30
    Width110 mm
    With explosion protectionNo
    With thermostatYes
    Circuit diagram Circuit diagram

    Downloads

    Instructions

    Datasheet

    PhotoTypeArticlenumberFeaturesKind
    JZ-17MN990001Adapter plate for Berlin 3000 housing (hardwired)Accessories
     

    Contact request

     

    Do you have questions or are you interested in our products?

    Please contact the electrician you trust or write us a message.

    Close Menu