Room hygrostat, flush-mounted, 24V AC to 230V AC, 35…85% r.H., two-way contact, alre frame, cover 50x50mm, pure white, gloss

FHY 101.060#21

Room hygrostat, flush-mounted, 24V AC to 230V AC, 35…85% r.H., two-way contact, alre frame, cover 50x50mm, pure white, gloss

The room hygrostat is designed for monitoring and controlling relative humidity, e.g. in business premises, apartments, conservatories, bathrooms, swimming pools, computer rooms and other spaces with a clean, non-aggressive environment. Relative humidity acting on a measuring strip activates a potential-free switch contact. The setpoint is adjusted using the adjustment knob located on the front. The setting range can be restricted.
Product inquiry
  • Art.-Nr.: UA020003

    Technical data

    maximum switching currentDehumid.: 5 (0.2) A ; Humid.: 2 (0.2) A
    maximum switching voltage230 V AC, 50 Hz
    mounting / attachmentflush mounting (deep socket recommended)
    colourpure white
    with thermostatNo
    switching contacttwo-way contact
    setting range, rel. air humidity lower value35%
    setting range, rel. air humidity upper value85%
    type of protectionIP30
    width81mm
    height85mm
    depth42,5mm
    RAL colour number (similar)9010
    with explosion protectionNo
    sensor elementKunststofffasern
    contact interlockingNo
    switching difference, can be adjustedNo
    switching differenceapprox. 5% r.H.
    number of outputs2
    output signalswitching (230 V AC / 24 V AC, 50 Hz)
    external settingYes
    operating voltagenone
    designBerlin UP
    electric connectionscrew terminals
    bearing temperature, lower value-20°C
    bearing temperature, upper value60°C
    housing materialplastic PC
    mechanical range reductionYes
    mediumair, not aggressive
    minimum switching voltage24 V AC / 50 Hz
    minimum switching current100 mA
    surface propertiesgloss
    potential free switching contactNo
    heating control functionNo
    cooling control functionNo
    switching elementmicroswitch
    On / Off switchNo
    switching power1150 W and/or 460 W
    protection classII, following appropriate mounting
    EMC safetyin accordance with DIN EN 60730
    operationrotary knob
    ambient temperature, upper value50°C
    ambient temperature, lower value0°C
    degree of contamination2
    maximum air humidity (non-condensing)95% r.H
    internal settingNo
    humidify / dehumidify control functionYes