Skip to main content

Capillary thermostat, wall mounting, 70…130…°C, adjustable hysteresis 2..20K, internal setting, capillary length 1.8m

JET-140 XF

Capillary thermostat, wall mounting, 70…130…°C, adjustable hysteresis 2..20K, internal setting, capillary length 1.8m

Monitoring or control of temperatures of non-aggressive, liquid and gaseous media. Especially suitable for wall mounting. For temperature control of non-aggressive gases in the duct, use the thermowell SW-200-12, for temperature control in non-aggressive fluids use the thermowell TH, in aggressive fluids use the thermowell NTH. Thermowells or protection coils are not included in the scope of delivery.
  • Art.-Nr.: JA043200

    Technical data

    Ambient temperature, lower value-20 °C
    Ambient temperature, upper value55 °C
    Bearing temperature, lower value-20 °C
    Bearing temperature, upper value55 °C
    Capillary length1,8 m
    ColourGrey
    Control range, lower value70 °C
    Control range, upper value130 °C
    Cooling control functionYes
    Degree of contamination2
    Device versionSurface-mounted unit
    Diameter sensor element9,6 mm
    Electric connectionScrew terminals
    Electronic controlNo
    External settingNo
    Function type (systems engineering)TW
    Heating control functionYes
    Housing materialPlastic
    Internal settingYes
    Length of sensor122 mm
    Max. sensor temperature145 °C
    Maximum air humidity (non-condensing)95 % r.H
    Maximum switching current15 (8) A
    Maximum switching voltage230 V AC, 50 Hz
    Mechanical range reductionNo
    MediumGas / liquid substances (not aggressive)
    Minimum switching current150 mA
    Minimum switching voltage24 V AC / 50 Hz
    Mounting / attachmentWall mounting
    Number of control ranges1
    Number of outputs2
    Operating voltageNone
    OperationInternal setpoint adjuster
    Output signalSwitching
    Potential free switching contactYes
    Protection classI
    RAL colour number (similar)7016/7035
    Rated impulse voltage4000 V
    Safety and EMCIn accordance with DIN EN 60730
    ScaleDegree Celsius
    Sensor elementCapillary tube
    Sensor materialCu (capillaries made from V2A)
    Surface propertiesMatt
    Switching contactTwo-way contact
    Switching difference, can be adjustedYes
    Switching differential adjustable from2 K
    Switching differential adjustable up to20 K
    Switching elementMicroswitch
    Switching power3450 W
    Type of protectionIP65
    With explosion protectionNo
    Circuit diagram Circuit diagram

    Downloads

    Instructions

    Datasheet

    PhotoTypeArticlenumberFeaturesKind
    SW-200-12C1809220Protective coil, 200mm, nickel-plated steel, inner x outer diameter 11x17mm, cable entry 11.8mmAccessories
    TH-140C1809409Immersion sleeve, 140mm, nickel-plated brass, inner x outer diameter 10x12mmAccessories
    JZ-04E6160133Capillary tube duct for JTF frost protection thermostats and JMT/WR/JET capillary controllersAccessories
    NTH-140C1809435Immersion sleeve, 140mm, V4A (1.4571), inner x outer diameter 10x12mmAccessories
     

    Contact request

      This form is currently undergoing maintenance. Please try again later.

    Do you have questions or are you interested in our products?

    Please contact the electrician you trust or write us a message.

    Close Menu